How to Use the fastQValidator Executable
Required Parameters:
-f : FastQ filename with path to be prorcessed.
Optional Parameters:
-l : Minimum allowed read length (Defaults to 10). -e : Maximum number of errors to display before suppressing them(Defaults to 20). -b : Raw sequence type: B - ACTGN only (Default) C - 0123. only BC - ACTGN or 0123.
Testing only Parameters:
-t : If "ReadOnly" is specified, the fastq will be read but not processed. This may be used for determining read time.
Usage:
./fastQValidator -f <fileName> -l <minReadLen> -e <maxReprotedErrors> -b <rawSeqType>
Examples:
../fastQValidator -f testFile.txt ../fastQValidator -f testFile.txt -l 10 -b BC -e 100 ./fastQValidator -f test/testFile.txt -l 10 -b BC -e 100 time ./fastQValidator -f test/testFile.txt -t ReadOnly
FastQ Validator Output
The FastQ Validator